Case study · MarLuc synopsis
University Hospital Bonn on-premise language model
DImplemented 2025–2026 · Health and life sciences · Germany · 3 min read · Version 1.0
University Hospital Bonn runs the open-weight DeepSeek-R1 model on a server in its own data centre so that radiologists can use a language model on patient text without it leaving the hospital. In a one-week pilot in July 2025, 22 radiologists rated it stable and most useful for tasks anchored in existing text, such as translating and correcting reports.
At a glance
- AI used
- Generative AI assistant: open-weight DeepSeek-R1 model hosted on the hospital's own server
- Implemented
- 2025–2026
- Grade
- Band D · Task support · Claimed only
- Headline result, as reported
- Open-weight DeepSeek-R1 run inside the hospital data centre; 22 radiologists rated it stable in a one-week pilot, by the hospital's own account
1The case
The facts, as reported by the sources below. Where a source is silent, the field says “Not reported”.
Organisation
University Hospital Bonn. University hospital in Bonn, Germany. The authors describe it as a university hospital with over 10,000 employees.
Canvas block: 6. Data and technology. Also 8. Governance and risk, 4. Operations and process
Business challenge
The challengeThe authors say that well-known commercial models are offered through cloud interfaces that need data to leave the hospital network, which raises confidentiality and regulatory concerns for patient information. Their aim was a self-hosted service that could process unanonymised patient data under least-privilege network rules.
How it was addressedThe hospital's radiology and research IT teams built an isolated, containerised stack on one on-premise server in the hospital data centre. It serves the open-weight DeepSeek-R1 model through vLLM with an Open WebUI front end. Before launch they sought approval from the board, the data protection and information security officers, the works council and the compliance department. In July 2025, 22 radiologists tried ten prompt templates for a week. The authors say the system is now a permanent service for hospital staff. [1][2][3]
Who implemented it
- DeepSeekModel or cloud providerProvides the DeepSeek-R1 open-weight model used in the pilot, as named in the paper.
- In-houseIn-houseUniversity Hospital Bonn Research-IT and Department of Diagnostic and Interventional Radiology: Designed, built, hosted and evaluated the system on the hospital's own server.
The authors released the deployment package under the Apache-2.0 licence on GitHub. No consultancy or integrator is named.
Technology (SEAM pillar E)
- T1
- T2
- T3
- T4
- T5
- T6
- T7
- T8
- T9
- Deployment
- Own infrastructure
- Vendors and products
- DeepSeek, DeepSeek-R1 (671 billion parameters, quantised), vLLM, Open WebUI, UKB-GPT (open-source deployment package)
- Where it was built in
- A chat interface for radiology text tasks on a single server with eight NVIDIA A100 80 GB GPUs in the hospital data centre, reached from the hospital intranet, with staff sign-in through the hospital's directory service. [1][2]
Technology types follow the SEAM taxonomy, the same list the SEAM Check uses.
What changed
What it cost
Not reported
What it saved
Governance and control
By the authors' account, the board, data protection officer, information security officer, works council and compliance department each set conditions: a 30-day chat retention limit, no staff usage statistics and voluntary use, a mandatory AI literacy course and a live security audit. All of this comes from the hospital's own paper.
- Accountable owner: Claimed
- Safe use: Claimed
- Human in the loop: Claimed
- Monitoring and assurance: Claimed
- Vendor AI: Claimed
- Agent controls: Not reported
- Standards and regulation: Claimed
Controls on each card:EvidencedOutside scrutinyClaimedMissingNot reported
| SEAM point | Evidence | What was done and how it was applied |
|---|---|---|
| S2 · Accountable owner | ◐ Claimed | The hospital's board of directors approved funding and the formal basis for deployment, by the authors' account; no named individual owner is reported. [1] |
| A1 · Safe use | ◐ Claimed | Staff must complete an AI literacy course before access, chat retention is capped at 30 days and the system is defined as radiology text support without autonomous clinical decisions, by the authors' account. [1] |
| A2 · Human in the loop | ◐ Claimed | The model is described as an assistive tool; users in the pilot reported where outputs needed correction, and the authors say ICD-10 coding still needed human checking. [1] |
| A3 · Monitoring and assurance | ◐ Claimed | Automated isolation tests and active isolation monitoring ran, and the authors report no external connectivity events in the pilot; error reports came from users, not blinded reviewers. [1] |
| A4 · Vendor AI | ◐ Claimed | The authors report a risk assessment of the open-source software components and defined supply chain and malicious model weights as threat scenarios. [1] |
| A5 · Agent controls | ○ Not reported | The service is a chat assistant. The authors list agent workflows as future work; no agent controls are reported. [1] |
| A6 · Standards and regulation | ◐ Claimed | Hospital compliance concluded that the EU AI Act applies and defined the hospital as a deployer, and the data protection and information security officers and the works council approved, by the authors' account. [1] |
● Evidenced: shown by an independent source. ◐ Claimed: the organisation's own account. ✕ Missing: an independent source shows the control was absent. ○ Not reported: the sources are silent.
What worked, what did not, what is unproven
Worked
- Stability and usability, rated highly by the 22 pilot users (stability median 10.0 out of 10).
- Tasks tied to an existing text, such as translation, linguistic correction and report simplification, with high ratings and no reported critical errors.
- Isolation tests passed, and the authors report no external connectivity events during the pilot.
Did not
- Open-ended conclusion drafting from findings had the highest number of critical errors, including two users reporting multiple critical errors.
- ICD-10 coding saved little time because the codes had to be verified.
- The authors say the older GPU server limited speed, with about 25 output tokens per second.
Unproven
- Whether the benefits hold in routine use beyond a one-week pilot with 22 radiologists.
- Whether clinical error rates are acceptable, as errors were reported by users and not reviewed blind.
- Any effect on cost, report turnaround or patient outcomes.
Timeline
- Jan 2025University Hospital Bonn and the University of Bonn report that local open-weight models can structure radiology findings with all data staying at the hospital[3]
- Jul 2025One-week pilot with 22 radiologists using ten prompt templates, after ethics approval[1]
- Mar 2026Hospital authors post a preprint describing the system as a permanent service for the hospital's staff[1]
2Grade and SEAM assessment
MarLuc's opinion, made on the evidence above. How we grade cases
Level of change and impact
- ATransformational
- BOperating model redesign
- CProcess change
- DTask supportGraded · Claimed only
- ENo measurable effect
- FFailure
- Claimed
- Not applicable
- Grade
- D · Task support
- Proof
- Claimed only
- Level of change
- Task support
Task support (Level 1, band D). Individuals use the model for text tasks; the report shows no change to a process, team structure or budget.
Radiologists use the tool for individual text tasks, so the main effect is on task support. The authors report ratings from a small one-week pilot and no cost, time or quality measures from routine use.
Controls against the SEAM minimum
Meets the SEAM minimum on the organisation's own account; no independent source shows the controls working. For T6 Open-source / locally hosted models, the SEAM minimum is human gates; the sources report human gates.
By the authors' account, access needs a completed AI literacy course, the system is an assistive tool without autonomous clinical decisions, and network isolation is tested automatically and monitored. All of this is the hospital's own description.
The SEAM view and lessons learnt
The main contribution is the control design: a locally hosted open-weight model with tested network isolation and a documented approval route. The evidence of benefit is thin, a one-week survey of 22 users. For a larger organisation, the transferable point is to limit early use to tasks anchored in existing text and to keep checking outputs by hand.
- Start with tasks tied to a source text.
- Treat chat logs on a local server as data that needs retention rules.
- Agree conditions with data protection, security and staff representatives before launch.
Evidence
Score 1 of 4. Self-reported: the results come from the hospital authors' own preprint and survey; the GitHub code is public but the outcomes are not independently checked.
Evaluation method. Self-reported company figures: a one-week pilot survey of 22 radiologists and system logs; error reports came from users, not blinded reviewers.
Sources disagree. The preprint describes over 10,000 employees at the hospital. The hospital's 2023 annual report was found in search but not read in full for this synopsis, so the staff figure is the authors' own.
Status. Ongoing: the authors describe it as the base for a permanent service for hospital staff, as of March 2026.
3Original sources
This synopsis draws on 3 sources, summarised by MarLuc. Read them in full before relying on any figure. If you think we have a fact or a grade wrong, challenge it and we will check and reply.
- [1]arXiv (University Hospital Bonn authors): Secure On-Premise Deployment of Open-Weights Large Language Models in Radiology (opens in a new tab)arxiv.org
- [2]GitHub (University Hospital Bonn): UKB-GPT, a single-host, isolation-first GenAI stack (opens in a new tab)github.com
- [3]University of Bonn: From text to structured information, securely with AI (14 January 2025) (opens in a new tab)uni-bonn.de
Version 1.0 · Published 15 Nov 2026 · Updated 15 Nov 2026 · Facts checked against sources 15 Nov 2026
Version history
- v1.015 Nov 2026First published
Related case studies
Found this useful? Share it with your network.
Know an AI deployment we should grade? Submit a case study
Where does your organisation sit?
The free SEAM Check takes ten minutes and shows where AI value is leaking. The free SEAM Report then gives your leadership team the full picture.