Case study · MarLuc synopsis

Epic Sepsis Model

E

Implemented 2018–2026 · Health and life sciences · US · 4 min read · Version 1.0

A sepsis prediction model built into a widely used hospital records system. An independent 2021 study at Michigan Medicine found poor performance; Epic disputed the method, later revised the model, and a 2026 study found better discrimination but low precision.

At a glance

No measurable effect: tested, no effect.

AI and automation used
Proprietary sepsis prediction model scoring hospital inpatients every 15 minutes inside the electronic health record; the original is described in one study as a penalised logistic regression
Implemented
2018–2026
Grade
Band E · No measurable effect · Partly proved
Headline result, as reported
Michigan Medicine study found the model missed 67% of sepsis cases and alerted on 18% of hospitalisations, 2021

1The case

The facts, as reported by the sources below. Where a source is silent, the field says “Not reported”.

Organisation

Epic Systems. Epic Systems is a US electronic health record vendor. Its sepsis model runs inside the Epic record at hospitals; the 2021 study covered Michigan Medicine, the academic health system of the University of Michigan. Size of Epic: Not reported in the sources used.

Canvas block: 4. Operations and process. Also 6. Data and technology, 8. Governance and risk

Business challenge

The challengeSepsis is a life-threatening reaction to an infection and a leading cause of hospital deaths in the US, per MedCity News. Hospitals adopted prediction tools to flag it early, and the 2021 study authors said the model's ability to identify sepsis had not been adequately evaluated despite widespread use.

How it was addressedEpic's sepsis model calculates a risk score from vital signs, laboratory values and other record data every 15 minutes, and hospitals choose the score that triggers an alert, per MedCity News. The study authors describe it as implemented at hundreds of US hospitals. Epic said the Michigan study did not take into account the analysis and fine tuning needed before real-world deployment, that its formula and inputs are available to administrators, and pointed to a University of Colorado Health preprint that found the model more accurate than that site's early warning score. [1][2][3][4][5][6]

Who implemented it

  • Epic SystemsSoftware vendorDeveloped and supplied the sepsis model within its electronic health record
  • In-houseIn-houseIndividual hospitals: Chose the alert threshold and deployed the model locally

Technology (SEAM pillar E)

T8 Predictive / ML modelsT2 Embedded AI in existing software
  1. T1
  2. T2
  3. T3
  4. T4
  5. T5
  6. T6
  7. T7
  8. T8
  9. T9
Deployment
Vendor SaaS
Vendors and products
Epic Systems, Epic Sepsis Model, Epic Sepsis Model version 2
Where it was built in
Built into the Epic electronic health record; scores are generated every 15 minutes and raise alerts for clinicians at a threshold each hospital sets. [2][4][5]

Technology types follow the SEAM taxonomy, the same list the SEAM Check uses.

What changed

Before: a risk score alerting clinicians at a threshold each hospital set. After the 2021 study: Epic revised the model, per STAT, recommending training on a hospital's own data and changing its definition of sepsis onset, and a 2026 study tested the updated model at four health systems. [1][2][3][4][5][6]

What it cost

Not reported

What it saved

Not reported [1][2][3][4][5][6]

Governance and control

The 2021 authors said hospitals should run their own validation studies, and the 2026 authors recommended local validation, workflows to manage false positives and alert silencing. Epic said tuning should happen before deployment. Accountable owner at each hospital and any regulatory review: Not reported.

  • Accountable owner: Not reported
  • Safe use: Claimed
  • Human in the loop: Evidenced
  • Monitoring and assurance: Missing
  • Vendor AI: Claimed
  • Agent controls: Not reported
  • Standards and regulation: Not reported

Controls on each card:EvidencedOutside scrutinyClaimedMissingNot reported

Governance evidence by SEAM point
SEAM pointEvidenceWhat was done and how it was applied
S2 · Accountable owner○ Not reportedNot reported.
A1 · Safe use◐ ClaimedEpic said real-world deployment needs analysis and fine tuning first, and later recommended training the model on each hospital's own data. [2][3]
A2 · Human in the loop● EvidencedThe model raises best practice advisory alerts for clinicians, who treated about half of sepsis cases without an alert in the county emergency department study. [5]
A3 · Monitoring and assurance✕ MissingThe 2021 authors said the model's ability to identify sepsis had not been adequately evaluated despite widespread use. [1]
A4 · Vendor AI◐ ClaimedEpic said its full mathematical formula and model inputs are available to administrators. [2]
A5 · Agent controls○ Not reportedNot reported.
A6 · Standards and regulation○ Not reportedNot reported. MedCity News says many decision-support models get little or no regulatory review, but does not state the model's regulatory status. [2]

● Evidenced: shown by an independent source. ◐ Claimed: the organisation's own account. ✕ Missing: an independent source shows the control was absent. ○ Not reported: the sources are silent.

What worked, what did not, what is unproven

Worked

  • The updated model showed improved discrimination for early sepsis prediction in the 2026 multicentre study: encounter-level area under the curve 0.82 to 0.92.
  • Epic maintained the model still helped clinicians provide early interventions, and pointed to a University of Colorado Health preprint that found it more accurate than that site's early warning score; the preprint was not opened.
  • At one 746-bed US academic trauma centre, a before-and-after study found that using the model as a screening test was associated with 44% lower odds of sepsis-related death; the authors call the study hypothesis generating and say more rigorous designs are needed.

Did not

  • Michigan Medicine found an area under the curve of 0.63, missed 1,709 of 2,552 sepsis patients (67%) and alerted on 6,971 of 38,455 hospitalisations (18%).
  • The model identified 183 of 2,552 sepsis patients (7%) who did not receive timely antibiotics, which the authors called low sensitivity compared with usual practice.
  • At two county emergency departments in 2023, at Epic's recommended threshold of 6, the original model had sensitivity of 14.7% and positive predictive value of 7.6%, with a median alert lead time of 0 minutes.
  • The updated model's positive predictive value stayed low at 0.13 to 0.26, with a high alert burden and high variation between sites.

Unproven

  • Whether the model improves patient outcomes: no randomised trial is reported in the sources used.
  • How the updated model compares with the original at the same sites, which the 2026 abstract states as an aim but does not report in its results.

Timeline

  1. Jun 2021Michigan Medicine researchers publish an external validation in JAMA Internal Medicine; Epic disputes the method[2]
  2. Oct 2022STAT reports Epic has revised the model, including a recommendation to train it on each hospital's own data[3]
  3. Dec 2022Harris Health in Houston implements the original model system-wide[5]
  4. 2023Two county emergency departments evaluate the original model over the year[5]
  5. Jun 2023Single-centre study at Prisma Health reports lower sepsis-related mortality after the alert was switched on[6]
  6. Aug 2023Four US health systems begin collecting data after implementing the updated model, to March 2025[4]
  7. Feb 2026JAMA Network Open publishes a multicentre validation of the updated model[4]

2Grade and SEAM assessment

MarLuc's opinion, made on the evidence above. How we grade cases

Level of change and impact

  1. ATransformational
  2. BOperating model redesign
  3. CProcess change
  4. DTask support
  5. ENo measurable effectGraded · Partly proved
  6. FFailure
Claimed
Not applicable
Grade
E · No measurable effect
Proof
Partly proved
Level of change
Not graded

No level assessed: band E. A deployed clinical alert tool whose performance, once independently checked, was weak and whose benefit is unproved; the updated model improved discrimination but not precision.

Graded E. The model was in use at hundreds of US hospitals, yet independent testing found weak performance and a heavy alert burden, and no source here shows a measured benefit across sites. No source reports a proved harm or that the tool was withdrawn, so it is not graded F. The revised model improved discrimination, but precision stayed low.

Controls against the SEAM minimum

Controls of the required type are reported, but the sources show them falling short in this case. For T8 Predictive / ML models and T2 Embedded AI in existing software, the SEAM minimum is monitoring; the sources report monitoring.

Hospitals set the alert threshold; independent researchers validated the model; the 2026 authors recommend local validation and alert silencing.

The SEAM view and lessons learnt

The gap sat between a vendor tool and the local population it was applied to. The first independent test came after hundreds of hospitals were using the model, and the vendor's reply was that local tuning matters, which the later recommendation to train on each hospital's data echoes. For a larger organisation, the transferable point is to validate any vendor prediction model on its own patients, at the alert threshold it will actually use, before relying on it.

  1. Validate vendor models on local data before go-live.
  2. Measure false alerts and clinician workload, not only accuracy.
  3. Re-test after the vendor changes the model.

Evidence

Score 3 of 4. Independent: three peer-reviewed validation studies by researchers not employed by the vendor; the vendor's counter-claims rest on an unopened preprint and an emailed statement.

Evaluation method. Peer-reviewed independent validation: retrospective cohort at Michigan Medicine (JAMA Internal Medicine, 2021), retrospective study at two county emergency departments (JAMIA Open, 2024) and prospective multicentre study of the updated model (JAMA Network Open, 2026); no randomised trial.

Sources disagree. Epic said the Michigan study ignored required fine tuning and that its threshold choice affected the result. The county emergency department study used Epic's recommended threshold of 6 and still reported poor characteristics. MedCity News reports the Michigan model as classifying patients correctly 63% of the time; the paper reports an area under the curve of 0.63, which is a different measure. The 2026 abstract and results body give different counts for non-sepsis encounters. Results vary by site: a single-centre before-and-after study at Prisma Health (2023) reported an area under the curve of 0.834 at its chosen threshold and lower sepsis-related mortality, against the poorer results at Michigan Medicine and two county emergency departments.

Status. Ongoing: the original model was still being implemented in December 2022 and evaluated through 2023; an updated model was validated at four health systems between August 2023 and March 2025.

3Original sources

This synopsis draws on 6 sources, summarised by MarLuc. Read them in full before relying on any figure. If you think we have a fact or a grade wrong, challenge it and we will check and reply.

Version 1.0 · Published 15 Nov 2026 · Updated 15 Nov 2026 · Facts checked against sources 15 Nov 2026

Version history
  1. v1.015 Nov 2026First published

Found this useful? Share it with your network.

Know an AI deployment we should grade? Submit a case study

Where does your organisation sit?

The free SEAM Check takes ten minutes and shows where AI value is leaking. The free SEAM Report then gives your leadership team the full picture.