Case study · MarLuc synopsis
Colonoscopy AI and endoscopist deskilling
DImplemented 2021–2022 · Health and life sciences · Poland · 3 min read · Version 1.1
A peer-reviewed study found that adenoma detection in colonoscopies done without AI fell after endoscopists had been using AI assistance routinely. It is observational, so the cause is not settled.
At a glance
- AI used
- Computer-aided detection: deep-learning software that flags possible polyps on the live colonoscopy image (ENDO-AID CADe, Olympus)
- Implemented
- 2021–2022
- Grade
- Band D · Task support · Partly proved
- Headline result, as reported
- After four Polish centres introduced AI polyp detection, adenoma detection in colonoscopies done without AI fell from 28.4% to 22.4% (observational, Lancet Gastroenterology & Hepatology, 2025)
1The case
The facts, as reported by the sources below. Where a source is silent, the field says “Not reported”.
Organisation
Four endoscopy centres in Poland (ACCEPT trial). Four endoscopy centres in Poland that took part in the ACCEPT trial (Artificial Intelligence in Colonoscopy for Cancer Prevention), part of the University of Oslo-led OperA project. The sub-study covers diagnostic colonoscopies by 19 experienced endoscopists, 16 gastroenterologists and three general surgeons, each with more than 2,000 colonoscopies.
Canvas block: 5. People and skills. Also 4. Operations and process
Business challenge
The challengeNumerous trials had shown that AI assistance raises adenoma detection in colonoscopy. The authors say little was known about how continuous AI use affects endoscopist skills, with suggestions it could be positive, by training clinicians, or negative, by reducing skills.
How it was addressedThe centres introduced AI computer-aided detection at the end of 2021, after which colonoscopies were randomly assigned to be done with or without AI by examination date. The study compared non-AI colonoscopies in the three months before and the three months after AI was introduced. The primary outcome was the change in adenoma detection rate in those non-AI colonoscopies. [1][2][3][4]
Who implemented it
- OlympusEquipment or robot makerSupplied the ENDO-AID CADe system used at the participating centres, per the American College of Gastroenterology summary.
- University of OsloUniversity or research labLeads the OperA project and the ACCEPT trial within which the study was nested.
- Academy of SilesiaUniversity or research labHome institution of lead author Marcin Romańczyk and co-author Krzysztof Budzyń, per the University of Oslo and ASCO Post pages.
Who deployed the system at each centre and under what contract: Not reported.
Technology (SEAM pillar E)
- T1
- T2
- T3
- T4
- T5
- T6
- T7
- T8
- T9
- Deployment
- Not reported
- Vendors and products
- Olympus, ENDO-AID CADe (OIP-1)
- Where it was built in
- Computer-aided detection used during live colonoscopy at four endoscopy centres in Poland. After introduction in late 2021, colonoscopies were assigned to be done with or without AI by examination date. [1][2]
Technology types follow the SEAM taxonomy, the same list the SEAM Check uses.
What changed
Before: adenoma detection in non-AI colonoscopy was 28.4% (226 of 795). After AI exposure: 22.4% (145 of 648), a relative fall of about 20%, by the authors' account. AI-assisted colonoscopies in the same period detected adenomas at 25.3% (186 of 734). The authors conclude that continuous exposure to AI might reduce detection in standard colonoscopy. [1][2][3][4]
What it cost
Not reported
Governance and control
The study is retrospective and observational. Its authors and an independent reviewer list confounding, a small endoscopist group and unreported withdrawal time as limits. The American Gastroenterological Association's 2025 guideline made no recommendation on AI-assisted colonoscopy, per the American College of Gastroenterology summary. Accountable owner and training for AI use: Not reported.
- Accountable owner: Not reported
- Safe use: Not reported
- Human in the loop: Claimed
- Monitoring and assurance: Evidenced
- Vendor AI: Not reported
- Agent controls: Not reported
- Standards and regulation: Outside scrutiny
Controls on each card:EvidencedOutside scrutinyClaimedMissingNot reported
| SEAM point | Evidence | What was done and how it was applied |
|---|---|---|
| S2 · Accountable owner | ○ Not reported | Not reported. |
| A1 · Safe use | ○ Not reported | Not reported. |
| A2 · Human in the loop | ◐ Claimed | The endoscopist performs the colonoscopy with or without AI; how clinicians were trained to use the prompts is not reported. [2] |
| A3 · Monitoring and assurance | ● Evidenced | The authors compared adenoma detection rates before and after AI introduction and reported the change; the American College of Gastroenterology summary notes that its own unit's colonoscopy quality programme tracks endoscopist detection rates and withdrawal times. [1][2] |
| A4 · Vendor AI | ○ Not reported | Not reported. |
| A5 · Agent controls | ○ Not reported | Not reported. |
| A6 · Standards and regulation | ◇ Outside scrutiny | The American College of Gastroenterology summary says the American Gastroenterological Association's 2025 living guideline made no recommendation on AI-assisted colonoscopy, because of very low certainty about long-term outcomes. [2] |
● Evidenced: shown by an independent source. ◐ Claimed: the organisation's own account. ✕ Missing: an independent source shows the control was absent. ○ Not reported: the sources are silent.
What worked, what did not, what is unproven
Worked
- Adenoma detection in AI-assisted colonoscopies was 25.3% (186 of 734) in the same period.
Did not
- Adenoma detection in non-AI colonoscopies fell from 28.4% to 22.4% after AI exposure (odds ratio 0.69, 95% CI 0.53 to 0.89).
- One author says it is the first study to suggest a negative effect of regular AI use on health professionals' ability to complete a patient-relevant task in medicine, and call the result concerning.
- Secondary outcomes did not show a significant decline: adenomas per colonoscopy 0.54 before and 0.43 after (p=0.071) and advanced adenomas per colonoscopy 0.062 and 0.063 (p=0.92).
Unproven
- Whether AI exposure caused the fall: the authors say factors other than AI use may have influenced the findings.
- Whether the finding holds for less experienced endoscopists; the authors say further studies are needed.
- Effect on patient outcomes such as cancer incidence: not measured.
- Whether the ACCEPT randomised trial will show the same effect. Its coordinator says the sub-study population is different and there is no supporting evidence of the same effect in the main trial population. Preliminary results were expected in late 2025; the sources opened do not report them.
Timeline
- 2021Four endoscopy centres in Poland, taking part in the ACCEPT trial, introduce AI polyp-detection tools at the end of the year; colonoscopies are then randomly assigned to be done with or without AI by date of examination[1]
- Sept 2021Study period begins; it runs to March 2022 and covers 1,443 non-AI colonoscopies, 795 before and 648 after AI was introduced[3]
- Aug 2025Study published in The Lancet Gastroenterology & Hepatology with a linked commentary by Omer Ahmad of University College London[3]
- Sept 2025American College of Gastroenterology's Evidence-Based GI summary notes confounding, 19 endoscopists and unreported withdrawal time[2]
2Grade and SEAM assessment
MarLuc's opinion, made on the evidence above. How we grade cases
Level of change and impact
- ATransformational
- BOperating model redesign
- CProcess change
- DTask supportGraded · Partly proved
- ENo measurable effect
- FFailure
- Claimed
- Not applicable
- Grade
- D · Task support
- Proof
- Partly proved
- Level of change
- Task support
Task support (Level 1, band D). AI is used as an assistant for individual endoscopists, and the study examines a possible side effect on skill. It is not graded F: no harm to patients, withdrawal of the tool or sanction is reported, and the cause of the fall in detection is not established.
Controls against the SEAM minimum
Controls not reported, so this cannot be checked. For T2 Embedded AI in existing software and T8 Predictive / ML models, the SEAM minimum is monitoring; the sources do not report any controls.
The sources opened do not describe operating controls. The study itself measured detection rates before and after AI introduction.
The SEAM view and lessons learnt
This is a rare piece of clinical evidence on the cost of relying on an assistant: performance without the tool may change after routine use. It is observational and the sources list real limits, so it is a signal to test, not a settled result. For a larger organisation using AI in skilled work, the transferable point is to keep measuring unassisted performance, to keep quality monitoring that tracks individuals, and to plan how skills are maintained.
- Measure unassisted performance as well as assisted performance.
- Keep individual quality monitoring in place after introducing an assistant.
- Treat skill loss as a risk to test with a controlled study.
Evidence
Score 2 of 4. Independent, with limits: peer-reviewed observational study in The Lancet Gastroenterology & Hepatology (2025), with a linked independent commentary. Retrospective, 19 endoscopists, differences between before and after groups.
Evaluation method. Peer-reviewed retrospective observational study at four centres (nested within the ACCEPT trial), comparing non-AI colonoscopies three months before and three months after AI introduction.
Sources disagree. The authors' reading is that AI exposure may have reduced detection. The American College of Gastroenterology reviewer says the groups differed (more female patients and less sedation after AI, p=0.005 and p=0.02), residual confounding is likely, and withdrawal time was not reported. The reviewer's own unit saw no significant detection difference with or without AI in a three-month trial (40.1% against 41.8%) and did not continue with the system.
Status. Published August 2025. Results from the ACCEPT randomised trial: Not reported.
3Original sources
This synopsis draws on 4 sources, summarised by MarLuc. Read them in full before relying on any figure. If you think we have a fact or a grade wrong, challenge it and we will check and reply.
- [1]The Lancet Gastroenterology & Hepatology: Endoscopist deskilling risk after exposure to artificial intelligence in colonoscopy, a multicentre, observational study (record via Europe PMC) (opens in a new tab)ebi.ac.uk
- [2]American College of Gastroenterology, Evidence-Based GI: Artificial intelligence in colonoscopy, could it be making us worse? (opens in a new tab)gi.org
- [3]The ASCO Post: Routine AI Assistance May Lead to Loss of Skills in Endoscopists, Study Shows (opens in a new tab)ascopost.com
- [4]University of Oslo, Institute of Health and Society: Continuous exposure to AI might reduce the skills of the endoscopist (opens in a new tab)med.uio.no
Version 1.1 · Published 15 Nov 2026 · Updated 15 Nov 2026 · Facts checked against sources 15 Nov 2026
Version history
- v1.115 Nov 2026Method update: standards and regulation (A6) relabelled "outside scrutiny" because the evidence is a regulator, court, auditor or similar body acting, not the organisation's own compliance.
- v1.015 Nov 2026First published
Related case studies
Found this useful? Share it with your network.
Know an AI deployment we should grade? Submit a case study
Where does your organisation sit?
The free SEAM Check takes ten minutes and shows where AI value is leaking. The free SEAM Report then gives your leadership team the full picture.